Part Number Hot Search : 
IDT74FC 1N5265B LHRF3133 1N5245 XFVOIP HD14002 74ALVC16 D486B
Product Description
Full Text Search
 

To Download HRF503A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  HRF503A silicon schottky barrier diode for rectifying ade-208-401 (z) rev. 0 oct. 1995 features low forward voltage drop and suitable for high effifiency rectifying. do-214 is suitable for high density surface mounting and high speed assembly. ordering information type no. laser mark package code HRF503A 503a do-214 outline 12 1. cathode 2. anode cathode mark mark 503a absolute maximum ratings (ta = 25c) item symbol value unit repetitive peak reverse voltage v rrm * 1 35 v average forward current i o * 2 5a non-repetitive peak forward surge current i fsm * 3 100 a junction temperature tj 125 c storage temperature tstg C40 to +125 c notes: 1. see fig.5 & fig.7 2. see fig.4 & fig.6 3. 10msec sine wave 1 pulse
HRF503A 2 electrical characteristics (ta = 25c) item symbol min typ max unit test condition forward voltage v f1 0.38 v i f = 3a v f2 0.45 i f = 5a reverse current i r 1.0 ma v r = 35v thermal resistance rth (j-a) 75 c/w glass epoxy substrate* rth (j-c) 35 c/w note: glass epoxy pcb 6.8 unit: mm 2.0 3.5 land size forward voltage v (v) f forward current i (a) f 10 10 ? 10 ? 10 ? 10 2 1.0 0 0.2 0.4 0.6 0.1 0.5 0.3 ta = 75 c ta = 25 c pulse test fig.1 forward current vs. forward voltage
HRF503A 3 reverse voltage v (v) r 0 10 10 10 ? 10 ? reverse current i (a) r ? 50 40 10 ? 10 ? 30 20 ta = 75 c ta = 25 c pulse test fig.2 reverse current vs. reverse voltage reverse voltage v (v) r 10 10 capacitance c (pf) 1.0 40 10 3 f = 1mhz pulse test 10 2 fig.3 capacitance vs. reverse voltage
HRF503A 4 0 150 50 100 25 75 125 ambient temperature ta ( c) average forward current (a) 0 2 1 3 4 duty = 2/3 duty = 1/2 rth (j-a) = 75 c/w vout = 3v duty = 1/3 5 6 dc (forward bias) fig.4 average forward current vs. ambient temperature 0 150 50 100 25 75 125 ambient temperature ta ( c) repetitive peak reverse voltage (v) 0 40 20 50 30 10 fm rth (j-a) = 75 c/w i = 5a duty = 2/3 5 15 25 35 45 dc (reverse bias) duty = 1/2 fig.5 repetitive peak reverse voltage vs. ambient temperature
HRF503A 5 0 150 50 100 25 75 125 case temperature tc ( c) average forward current (a) rth (j-c) = 35 c/w vout = 3v duty = 1/3 duty = 1/2 0 2 1 3 4 5 6 duty = 2/3 dc (forward bias) fig.6 average forward current vs. case temperature 0 150 50 100 25 75 125 cace temperature tc ( c) repetitive peak reverse voltage (v) 0 40 20 50 30 10 fm rth (j-c) = 35 c/w i = 5a 5 15 25 35 45 dc (reverse bias) duty = 2/3 duty = 1/2 duty = 1/3 fig.7 repetitive peak reverse voltage vs. case temperature
HRF503A 6 package dimensions 0.25 8.0 0.3 3.0 0.2 4.0 0.2 1.2 0.3 7.0 0.2 2.1 0.2 cathode mark 503a lot no. 2 1 hitachi code jedec code eiaj code weight (g) do-214 do-214 0.16 1 2 cathode anode unit: mm